Products
Question
Reactor attention to the use of magnetic reactor
Time:2018-05-31 Click:868
1, Before the operation of the magnetic reactor, it should be carefully checked for abnormality. During the normal operation of the reactor, the upper cover and the terminal on the board must not be opened to avoid electric shock.
2, The magnetic reactor measuring instrument should be regularly calibrated to ensure accurate and reliable operation.
3, the temperature of the magnetic reactor heating rate should not be too fast, pressure should also be carried out slowly, especially the stirring speed of the reactor, only allowed to slowly increase speed. In the event of a power outage, the speed control knob should be returned to zero.
4, The magnetic reaction vessel must not be cooled quickly to prevent damage caused by excessive temperature differential pressure.
5, When the magnetic reactor is operating, the water jacket between the coupling and the kettle cover must pass cooling water to control the working temperature of the reactor magnet steel and avoid demagnetization.
6, The magnetic reaction kettle must not be used to tap the bolt and nut connector under high pressure.
7, After being used for a period of time, the magnetic reaction vessel bursting film will be aged and fatigued, reduce the bursting pressure, and may also have media adhesion, which affects the sensitivity of the reaction vessel and should be replaced regularly. Generally, one is replaced once to prevent failure.
8, magnetic reactor is strictly prohibited with pressure removal.
2, The magnetic reactor measuring instrument should be regularly calibrated to ensure accurate and reliable operation.
3, the temperature of the magnetic reactor heating rate should not be too fast, pressure should also be carried out slowly, especially the stirring speed of the reactor, only allowed to slowly increase speed. In the event of a power outage, the speed control knob should be returned to zero.
4, The magnetic reaction vessel must not be cooled quickly to prevent damage caused by excessive temperature differential pressure.
5, When the magnetic reactor is operating, the water jacket between the coupling and the kettle cover must pass cooling water to control the working temperature of the reactor magnet steel and avoid demagnetization.
6, The magnetic reaction kettle must not be used to tap the bolt and nut connector under high pressure.
7, After being used for a period of time, the magnetic reaction vessel bursting film will be aged and fatigued, reduce the bursting pressure, and may also have media adhesion, which affects the sensitivity of the reaction vessel and should be replaced regularly. Generally, one is replaced once to prevent failure.
8, magnetic reactor is strictly prohibited with pressure removal.